A trap’s capacity curve must be read at the differential pressure it experiences, including downstream backpressure.
Define the Thermal Model
Differential pressure is the inlet pressure minus the outlet backpressure on a compatible basis. Spirax Sarco’s drainage analysis connects trap capacity to this difference rather than supply pressure alone. The actual type and orifice curve remain necessary; pressure arithmetic cannot manufacture a capacity rating.
Compare a Hypothetical Case
Imagine an inlet operating at 3.0 barg. With 0.5 barg at the outlet, the difference is 2.5 bar. If the return condition rises to 2.5 barg, the difference becomes only 0.5 bar. Both cases have the same inlet value, yet a capacity check at 3 bar would represent neither of them.
Complete the Engineering Review
List inlet and return conditions over the duty envelope, including low-load pressure changes and any lift or return-line resistance. Read the selected trap’s published capacity at the resulting differential and stated condensate condition. Keep the required load and available capacity on separate lines so that a convenient line-size match does not substitute for drainage review.
For a processing-tank interface, obtain the actual utility schematic. The example does not specify a trap or operating pressure for HM equipment. If the system cannot provide the required positive driving pressure, discuss the complete drainage arrangement rather than assuming a larger nominal trap resolves it.
Does the stated capacity correspond to the inlet/outlet pressure conditions?
This blank worksheet is for your own project. It contains no H M machine trial result.
| Review field | Reference or result | Responsible person |
|---|---|---|
| Inlet pressure over load range | To complete | To complete |
| Return backpressure and lift basis | To complete | To complete |
| Actual differential pressure | To complete | To complete |
| Selected hot-condensate capacity curve | To complete | To complete |
Customer Questions
Does supply pressure equal trap differential?
Only if outlet pressure is appropriately negligible on the same basis.
Can line size prove capacity?
Use the selected type and orifice curve.
Is one design-point difference enough?
Check the required operating envelope.
Related Equipment References
Review the actual offered equipment and application separately from this educational example.
Primary References
These references support the technical principles discussed in this guide. The worked examples and review questions are educational.